Description
Characteristics
•The two-wire system transmitter, which is based on current loop power supply, can effectively reduce the wiring costs and power consumption and enhance the anti-interference ability.
• HART communication protocol.
• 4-20mA output.
• While connecting to the thermal resistance transducer, it has short-circuit and open-circuit monitoring function; while connecting to the thermocouple transducer, it has open-circuit monitoring function.
•By using the 3 built-in operating buttons together with the highlighted LCD display, the parameters of the transmitter can be set locally conveniently. In addition, the remote parameter configuration of the transmitter can be realized easily by HART modem.
•The rotatable LCD display enhances the flexibility of transmitter installation and displays the percentage of current measured value in the full scale, current measured value and its unit and the sensor type and the diagnostic messages of transmitter etc.
•The protection level of shell is IP67, which can be applied to the outdoor usage.
• Support all the transducers conforming to IEC751 and IEC584.
Technical parameters
Input
Sensor type:
WP-301A/B1: Pt100, Pt1000, Cu50, Cu100
WP-301A/B2: S, R, B, K, N, E, J, T, WRe3-25
WP-301A/B3: Pt100, Pt1000, Cu50, Cu100
S, R, B, K, N, E, J, T, WRe3-25
Accept the user’s designation
Connection modes
WP-301A/B1: A two/three/four-wire system thermal resistance transducer
WP-301A/B2: A thermocouple transducer and a thermal resistance transducer (three-wire) can work as the cold junction compensation or set the fixed cold-junction temperature to compensate without connecting to the thermal resistance transducer, or use the built-in thermal resistance transducer of the transmitter to conduct cold junction compensation (The compensation precision will effect the final measurement accuracy.)
WP-301A/B3: adopt the connection mode of WP301A/B1 or WP301A/B2 according to the needs
Measurement range
Appendix 1: List for the inputted sensor types and accuracies Response time
≤250ms with sensor short-circuit and open-circuit monitoring
Output
Two-wire system 4-20mA
HART
Load resistance Ra
Ra≤(Us-14.7V)/0.024A, Us is the loop voltage
Sensor faults
Short circuit: accept the user’s designation (3.5~3.75mA)
Open circuit: accept the user’s designation (21~23mA)
System faults
Can be set as 3.2mA or 24mA
Measurement accuracy
Accuracy (Digital measurement accuracy)
See appendix 1: List for the inputted sensor types and accuracies
Analog output accuracy
0.025% full scale
Long term drift
The first year <0.2% full scale
Temperature effects
See appendix 2: Effects of ambient temperature
Rated operating conditions
Ambient temperature
-40~85℃ -20~60℃ (Anti-explosion type)
Condensation
Allowable
Electromagnetic compatibility
GB/T 17626, Grade 3
Protection grade according to EN 60529
IP67
Design
Shell
Aluminium die casting
Weight
1kg (not including temperature sensor)
Size
See Appendix 3: Dimensional drawing for two-wire system intelligent temperature transmitter
Cable sealed tube connecting thread
M20×1.5 other threads need to use adapters
Connection of sensor
Integrated type
split type
Display and control
Size of display
33×23mm
Display precision
5 digits
Unit (Switchable)
℃ or ℉
Settings
The 3 buttons of panel or HART handle and configuration software which is compatible with HART protocol
Power supply
15~36V DC
Electric isolation
Between the input and output Ueff = 1 kV, 50 Hz, 1 min
Certificate and licence
Flame-proof type
ExdⅡCT6
Intrinsic safety type
ExiaⅡCT6